PRESSURE INDEPENDENT CONTROL VALVE (PICV)

  • Allows, in a single device, hydraulic balancing of the circuit and adjustment of the flow rate to the terminals.
  • Circuit balancing is carried out using an automatic regulator capable of working with a pressure differential of up to 4 bar at the valve ports
  • Possibility, during installation, of easily pre-adjusting the flow rate to between 10% and 100% of the nominal value using a graduated scale indicator.
  • Flow rate adjustment can take place using an actuator controlled by an external regulator, in accordance with the thermal load.
  • Extremely compact, suitable for installation even in small spaces.
  • Fitted for connection to pressure test gauges for checking the system operating parameters

FCU VALVES

The pre-assembled group for terminal units is compact and able to shut-off, adjust and filter the secondary circuit of the terminal unit. It also allows to perform maintenance and setting operations of the system. It allows the connection of fan coils, cold beams or ceiling conditioning systems with the main distribution network. Complete with insulation suitable for both heating and cooling. Available with Venturi device for flow rate measurement.

AUTO FLOW CONTROL VALVES

AUTOFLOW® devices are automatic flow rate regulators, which keep the flow rate constant in air conditioning and plumbing system circuits. They are used to automatically balance the plumbing system, guaranteeing the design flow rate to each terminal. The devices are available in both the flow rate regulator simple version and the shut-off ball equipped version.

TWO WAY & THREE WAY VALVES

Motorised ball valves allows both automatic shut-off and diversion of the thermal medium in air conditioning or water supply systems. The use of these components is particularly indicated in hydrothermal

systems thanks to the following features:

  • possibility of being installed upside-down;
  • possibility of being opened and closed thanks to the manual control lever on the actuator;
  • no seepage;
  • short operating times (valve – opening/closing);
  • can function with high differential pressures;
  • low head losses;
  • combination with any type of 3-contact actuator;
  • in the three-way versions, possibility of use in diversion or mixing mode.

AIR SEPERATORS

Deaerators are used to continuously remove the air contained in the hydraulic circuits of heating and cooling systems. The air discharge capacity of these devices is very high. They are capable of automatically removing all the air present in the system down to micro-bubble level. The circulation of fully deaerated water enables the systems to operate under optimal conditions, free from any noise, corrosion, localised overheating or mechanical damage. In the threaded versions it is available for installation on horizontal pipes, and with adjustable T-fitting for installation on horizontal and vertical pipes. Flanged and weld-end DISCAL® deaerators are supplied complete with hot pre-formed shell insulation to ensure perfect heat insulation when used in both hot and chilled water systems. Optional insulation is available for the threaded model with 3/4” and 2” drain.

AIR VENTS

Automatic air vent valves are designed to remove the air that accumulates in heating, air conditioning and refrigeration systems without the need for manual intervention. This prevents harmful phenomena that may compromise the life and the performance of the

Heating system and which include:

  • corrosion due to the oxygen;
  • pockets of air trapped in the heating emitters;
  • cavitation in the circulation pumps;
  • noise from air passing through the pipes.

These high capacity air vent valves are ideal for use in large piping systems and can also be installed in horizontal sections.

PREASSURE REDUCING VALVES ( PRV)

Pressure reducing valves are installed in residential water systems to reduce and stabilise inlet pressure from the water supply network which is generally too high and variable for domestic systems to work properly. The 533...H series was designed for small systems, such as apartments, and to protect water storages, where size and lack of noise are important aspects. This specific series of pressure reducing valves is certified according to the EN 1567 standard for operating with inlet water temperatures of up to 80°C.

THERMOSTATIC MIXING VALVES

The thermostatic mixing valve is used in systems that produce domestic hot water. It is designed to maintain the preset temperature of the mixed water delivered to the user outlet, when there are variations in the temperature and pressure of the hot and cold water at the inlet, or in the drawn-off flow rate. These devices are also available with fittings complete with strainers and check valves on the hot and cold water inlets

THERMAL BALANCING VALVE

The thermostatic regulator is used for automatic balancing of recirculation loops in domestic hot water distribution systems, so as to ensure that all parts of the system reach the required temperature. It is also equipped with a by-pass mechanism, to be used in the event of thermal disinfection against Legionella. The device is produced in a version complete with automatic thermostatic thermal disinfection function or fitted for disinfection against Legionella, with the possibility of installing a special cartridge for disinfection controlled by an actuator. The regulator complies with specifications by DVGW (according to standard W554) and by WRAS (UK).

ELECTRONIC MIXING VALVE

The electronic mixing valve is used in centralised systems that produce and distribute domestic hot water. Its function is to guarantee and maintain the temperature of the domestic hot water delivered to the user when there are variations in the temperature and pressure of the hot and cold water at the inlet or in the draw-off flow rate. This particular series of electronic mixing valves is equipped with a specific regulator that controls a set of programs for circuit thermal disinfection against Legionella. In addition it enables checking the temperature and time for thermal disinfection are actually reached and undertaking the appropriate corrective action. All the parameters are updated every day and logged, with temperatures recorded every hour. Depending on the type of system and habits of the user, it is possible to program temperature levels and operation times in the most appropriate manner. In addition, it is fitted for a monitoring and remote control connection.

BACKFLOW PREVENTERS

The charging unit assembly is composed of a shut-off valve with an inspectable strainer, a BA type controllable reduced pressure zone backflow preventer and a pre-adjustable filling unit. It is installed on the water inlet pipe in sealed heating systems and its main function is to maintain the pressure of the system stable at a set value, providing automatically a re-fill of the missing water. This product has the peculiarity of being pre-adjustable. That means it can be adjusted at a desired pressure value before the system filling stage. The backflow preventer is inserted to prevent the contaminated water of the closed heating circuit from flowing back into the domestic water supply network, in compliance with EN 1717 standard prescriptions. The device is proposed complete with pre-formed shell insulation and with a compact dimension design to make its hydraulic installation easier

SAFETY RELEIVE VALVE FOR THERMAL SYSTEMS

  • Safety relief valve for solar thermal systems.
  • Brass body. Chrome plated.
  • Female connections. PN 10.
  • Temperature range: -30–160°C.
  • Max. percentage of glycol: 50%.
  • Oversized discharge outlet.
  • Discharge rating: 1/2” - 50 kW;
    3/4” - 100 kW.
  • TÜV certified to TRD 721 - SV 100 § 7.7.
  • Settings: 2,5 - 3 - 4 - 6 - 8 - 10 bar

WELDED EXPANSION VESSEL ONLY FOR PRIMARY CIRCUIT OF SOLAR THERMAL SYSTEMS

  • Welded expansion vessel only for primary circuit of solar thermal systems, EC certification.
  • Bladder membrane.
  • Max. working pressure: 10 bar.
  • System working temperature range: -10–120°C.
  • Membrane working temperature range: -10–70°C.
  • Max. percentage of glycol: 50%.
  • Conformity to EN 13831 standard.

BALL VALVE FOR SOLAR THERMAL SYSTEM

  • Ball valve for solar thermal system.
  • Body and ball in stainless steel AISI 316.
  • PN 63.
  • Female connections.
  • Handle in stainless steel AISI 304.
  • Temperature range: -30–200°C.
  • Max. percentage of glycol: 50%.

SOLAR STORAGE TO BOILER CONNECTION KIT

Solar storage-to-boiler connection kit, without thermal integration. Consisting of:

  • thermostatic anti-scald mixing valve, adjustable with knob, for solar thermal systems. Complete with strainers and check valves at the inlets;
  • diverter valve with three-contact actuator, with auxiliary microswitch;
  • thermostat with probe for solar thermal system, for operating diverter valve. Display showing temperature.
  • pre-formed shell protective cover.

Diverter-to-mixing valve coupling with adjustable position of the inlet and outlet connections.

Mixing valve

  • Dezincification resistant alloy body.
  • Max. working pressure: 10 bar.
  • Adjustment temperature range: 35–55°C.
  • Max. inlet temperature: 100°C.

Diverter valve

  • Brass body.
  • Max. working pressure: 10 bar.
  • Temperature range: -5–110°C

Actuator

  • Three-contact type.
  • Supply: 230 V (ac).
  • Power consumption: 8 VA.
  • Auxiliary microswitch contact rating: 0,8 A (230 V).
  • Ambient temperature range: 0–55°C.
  • Protection class: IP 44 (vertical stem).
    IP 40 (horizontal stem).
  • Operating time: 10 s.
  • Cable length: 1 m.
  • Thermostat with probe
  • Supply: 230 V (ac).
  • Adjustable temperature range: 25–50°C.
  • Factory setting: 45°C.
  • Box protection class: IP 54.

TEMPERATURE & PRESSURE REFIEF VALVE FOR SOLAR THERMAL SYSTEMS

  • Temperature and pressure relief valve.
  • For solar thermal systems, to protect the hot water storage.
  • Dezincification resistant alloy body.
  • Chrome plated.
  • Setting temperature: 90°C.

Discharge rating:

  • 1/2” x Ø 15: 10 kW.
  • 3/4” x Ø 22: 25 kW.
  • Settings: 6 - 7 - 10 bar.
  • Settings certified to EN 1490:
  • 7 - 10 bar.

AUTOMATIC AIR VENT FOR SOLAR HEATING SYSTEMS

Automatic air vent for solar thermal systems.

  • Brass body. Chrome plated.
  • Max. working pressure: 10 bar.
  • Max. discharge pressure: 5 bar.
  • Temperature range: -30–180°C.
  • Max. percentage of glycol: 50%.

Shut-off cock complete with seal.

  • Brass body. Chrome plated.
  • Max. working pressure: 10 bar.
  • Temperature range: -30–200°C.
  • Max. percentage of glycol: 50%

GMC REFRIGERAZIONE Valves

The check valves are classified “Pressure accessories” All the product range is suitable for use with fluids therefore not toxic, not inflammable and not explosive fluids; to this macro Group belongs also the refrigerant fluids listed and classified in A1 Group of Annex E of standard EN 378-1.

VALVES FOR HVAC, PLUMBING & SOLAR

VALVES FOR HVAC, PLUMBING & SOLAR

A leading Italian manufacturer of high-quality components for heating, plumbing, air conditioning,
heat metering and renewable systems, for domestic and industrial plants.

Pressure Independent Control Valve (PICV)

one

FCU VALVES

two

AUTO FLOW CONTROL VALVES

three

TWO WAY & THREE WAY VALVES

four

AIR SEPERATORS

five

AIR VENTS

six

Preassure Reducing Valves ( PRV)

seven

THERMOSTATIC MIXING VALVES

eight

THERMAL BALANCING VALVE

nine

ELECTRONIC MIXING VALVE

ten

BACKFLOW PREVENTERS

eleven

SAFETY RELEIVE VALVE FOR THERMAL SYSTEMS

twelve

WELDED EXPANSION VESSEL ONLY FOR PRIMARY CIRCUIT OF SOLAR THERMAL SYSTEMS

thirteen

BALL VALVE FOR SOLAR THERMAL SYSTEM

fourteen

SOLAR STORAGE TO BOILER CONNECTION KIT

fifteen

TEMPERATURE & PRESSURE REFIEF VALVE FOR SOLAR THERMAL SYSTEMS

sixteen

AUTOMATIC AIR VENT FOR SOLAR HEATING SYSTEMS